ΠΊΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ ch05 lg
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌ LG
LG CH-01 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² ΠΏΠ»Π°ΡΡ (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π²Π½ΡΡΡΠ΅Π½Π½Π΅Π³ΠΎ ΠΊΠΎΠΌΠ½Π°ΡΠ½ΠΎΠ³ΠΎ, Π½Π°ΡΡΠ΅Π½Π½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ β ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ°
LG CH-02 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ°: Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈΠ»ΠΈ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ°
LG CH-03 ΠΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅Ρ ΡΠ°Π±ΠΎΡΠ°Π΅Ρ ΠΎΠ΄Π½ΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ ΠΈ Π½Π° ΠΎΠ±ΠΎΠ³ΡΠ΅Π² ΠΈ Π½Π° ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΠ΅ Π²ΠΎΠ·Π΄ΡΡ Π°
LG CH-04 ΠΠΊΠ»ΡΡΠ΅Π½Π° ΡΠΈΡΡΠ΅ΠΌΠ° Π·Π°ΡΠΈΡΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ
LG CH-05 ΠΡΠΈΠ±ΠΊΠ° ΠΎΠ±ΠΌΠ΅Π½Π° Π΄Π°Π½Π½ΡΠΌΠΈ ΠΌΠ΅ΠΆΠ΄Ρ ΠΊΠΎΠΌΠ½Π°ΡΠ½ΡΠΌ ΠΈ Π½Π°ΡΡΠΆΠ½ΡΠΌ Π±Π»ΠΎΠΊΠ°ΠΌΠΈ ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ
LG CH-06 Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΈΡ ΠΈΡΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΡΡ ΡΡΡΡΠΎΠΉΡΡΠ² Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° β ΡΠ΅Π»Π΅, ΠΊΡΠ°ΡΠΊΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ
LG CH-07 Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ Π²ΡΠ΅Π³ΠΎ Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° Π΄Π»ΠΈΡΠ΅Π»ΡΠ½ΠΎΠ΅ Π²ΡΠ΅ΠΌΡ Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ
LG CH-08 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π΄Π²ΠΈΠ³Π°ΡΠ΅Π»Ρ Π²Π΅Π½ΡΠΈΠ»ΡΡΠΎΡΠ°
LG CH-09 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ 4 β Ρ ΠΎΠ΄ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠ»Π°ΠΏΠ°Π½Π°
LG CH-10 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π΅Π½ ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΊΠΎΡΠΏΡΡΠ° ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ (ΠΎΠ±ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅)
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΈΠ½Π²Π΅ΡΡΠΎΡΠ½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = IPM Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠ΅ΠΉ lg (ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ ΠΏΠΎ ΡΠΎΠΊΡ)
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 1 ΡΠ°Π·
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ ΠΠ’ = 2 (ΠΌΠ°ΠΊΡ. ΡΠΎΠΊ)
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 2 ΡΠ°Π·Π°
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ LG β DC Π‘ΡΡΠ»ΠΊΠ° ΠΠΈΠ·ΠΊΠΈΠΉ Volt
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 3 ΡΠ°Π·Π°
Π‘Π»ΡΡΠ°ΠΉ ΠΎΡΠΈΠ±ΠΊΠΈ = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 140V
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = LG β ΠΠΈΠ·ΠΊΠΎΠ΅ / ΠΡΡΠΎΠΊΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =4 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β Low / High ΠΡΠ΅ΡΡ ΠΊΠΎΠΌΠΌΡΡΠ°ΡΠΎΡ ΠΎΡΠΊΡΡΡΠΎΠΌ ΡΠΈΠΊΠ»Π΅
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ LG β AC ΠΠΈΠ·ΠΊΠΈΠΉ / ΠΏΠ΅ΡΠ΅ΠΌΠ΅Π½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ°, ΠΏΠΎΠ²ΡΡΠ΅Π½Π½ΠΎΠ΅ Π½Π°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = 5 ΡΠ°Π·
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = DC ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ ΠΏΠΎΠ·ΠΈΡΠΈΠΈ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =ΠΌΠΈΠ³Π°Π΅Ρ 6 ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠΎΠ·ΠΈΡΠΈΡ ΠΎΠ±Π½Π°ΡΡΠΆΠ΅Π½ΠΈΡ ΠΎΡΠΈΠ±ΠΎΠΊ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = PSC Fault (ΡΠ΅Π°ΠΊΡΠΎΡ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = 7 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ ΠΏΠΎ ΡΠΎΠΊΡ Π½Π° Β«IGBTΒ»
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = DC Π‘ΡΡΠ»ΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΠΠΎΠ»ΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =8 ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 420V
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π²ΡΠΏΡΡΠΊΠ½ΠΎΠΉ ΡΡΡΠ±Ρ Temp. ΠΡΡΠΎΠΊΠΈΠΉ (ΠΈΠ½Π². Compressor)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 3 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG Π²Π½ΡΡΡ. Π±Π»ΠΎΠΊΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β Π‘Π±ΡΠΎΡ Π΄Π°ΡΡΠΈΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ°. (105Β°C)
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π²ΡΠΏΡΡΠΊΠ½ΠΎΠΉ ΡΡΡΠ±Ρ Temp. ΠΡΡΠΎΠΊΠΈΠΉ (Cons. Compressor)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 3 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =3 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β Π‘Π±ΡΠΎΡ Π΄Π°ΡΡΠΈΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ°. (105Β°C)
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = CT ΡΠ΅ΠΏΠΈ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΠ’ ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠ΅ΠΏΠΈ Off
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe Π΄Π°ΡΡΠΈΠΊΠ° INV. ΠΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄Π°ΡΡΠΈΠΊ Π²ΠΎΠ·Π΄ΡΡ Π° (ΠΎΡΠΊΡΡΡΡ / ΠΠΎΡΠΎΡΠΊΠΈΠ΅
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =4 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄ΠΈΡ. Π’ΡΡΠ±Π° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =5 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΡΠ°ΡΡΠ²Π°ΡΡΠ°Ρ ΡΡΡΠ±Π° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =ΠΌΠΈΠ³Π°Π΅Ρ 6 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe ΠΠΈΠ½ΡΡΡ Sensor.
ΠΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =7 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe & Π΄Π°ΡΡΠΈΠΊ Π²ΠΎΠ·Π΄ΡΡ Π° (ΠΎΡΠΊΡΡΡΡΠΉ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = 8 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΠ²ΠΎΠΉΠ½ΠΎΠΉ Π΄Π°ΡΡΠΈΠΊ ΠΎΡΠΊΠ»ΡΡΠ΅Π½. Π Π°Π·ΠΎΠΌΠΊΠ½ΡΡΠΎ ΡΠΎΠ΅Π΄ΠΈΠ½Π΅Π½ΠΈΠ΅ Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π½Π°Π³Π½Π΅ΡΠ°Π½ΠΈΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΈ Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²ΠΎΠ·Π΄ΡΡ Π° Π² ΠΠ°ΡΡΠΆΠ½ΠΎΠΌ Π±Π»ΠΎΠΊΠ΅. ΠΠ΅ΠΎΠ±Ρ ΠΎΠ΄ΠΈΠΌΠΎ ΠΏΡΠΎΠ²Π΅ΡΠΈΡΡ Π΄Π°ΡΡΠΈΠΊΠΈ ΠΈ ΠΈΡ ΠΏΠΎΠ΄ΠΊΠ»ΡΡΠ΅Π½ΠΈΠ΅, ΡΠΎΠ΅Π΄ΠΈΠ½ΠΈΡΠ΅Π»ΡΠ½ΡΠ΅ ΠΏΡΠΎΠ²ΠΎΠ΄Π° Π»ΠΈΠ±ΠΎ ΠΏΠ»Π°ΡΡ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ.
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΠ° ΠΠΌΠΊΠΎΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 5 ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΠ° ΠΠΌΠΊΠΎΡΡΡ ΠΠΎΠΌΠ±ΠΈΠ½Π°ΡΠΈΡ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΡΠΈΠ±ΠΊΠ° ΡΠ²ΡΠ·ΠΈ (ΠΡΡΡΡΠΉ ΠΡΠΊΡΡΡΡΠΉ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 5 ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =3 ΡΠ°Π·Π°
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ»ΠΎΡ ΠΎ / ΠΠΎΡΠ΅ΡΡ ΡΠ²ΡΠ·ΠΈ
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = EEPROM ΠΊΠΎΠ½ΡΡΠΎΠ»ΡΠ½ΠΎΠΉ ΡΡΠΌΠΌΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΠΎΠ½ΡΡΠΎΠ»ΡΠ½Π°Ρ ΡΡΠΌΠΌΠ° Mis-Match
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄ΠΈΡ. Π’ΡΡΠ±Π° Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠΎΠ½Π΄. Π’Π΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ° ΠΡΡΠΎΠΊΠΈΠΉ (65Β°C)
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG Π²Π½ΡΡΡ. Π±Π»ΠΎΠΊΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Temp. ΠΡΡΠΎΠΊΠΈΠΉ (85Β°C)
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =5 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 420V
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΏΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΠ½ΡΡΡΠ΅Π½Π½ΠΈΠΉ Π±Π»ΠΎΠΊ:
02 — Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΈΡΠΏΠ°ΡΠΈΡΠ΅Π»Ρ ΠΊΠΎΡΠΎΡΠΊΠΎΠ·Π°ΠΌΠΊΠ½ΡΡ ΠΈΠ»ΠΈ ΠΎΠ±ΡΡΠ² Π² ΡΠ΅ΠΏΠΈ;
ΠΠ½Π΅ΡΠ½ΠΈΠΉ Π±Π»ΠΎΠΊ:
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ ch05 lg
ΠΠ±ΡΠ»ΡΠΆΠΈΠ²Π°Π½ΠΈΠ΅ ΠΈ ΡΠ΅ΠΌΠΎΠ½Ρ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² Π² ΠΠΎΡΠΊΠ²Π΅ ΠΈ ΠΠ
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌ LG
LG CH-01 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² ΠΏΠ»Π°ΡΡ (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π²Π½ΡΡΡΠ΅Π½Π½Π΅Π³ΠΎ ΠΊΠΎΠΌΠ½Π°ΡΠ½ΠΎΠ³ΠΎ, Π½Π°ΡΡΠ΅Π½Π½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ β ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ°
LG CH-02 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ°: Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈΠ»ΠΈ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ°
LG CH-03 ΠΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅Ρ ΡΠ°Π±ΠΎΡΠ°Π΅Ρ ΠΎΠ΄Π½ΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ ΠΈ Π½Π° ΠΎΠ±ΠΎΠ³ΡΠ΅Π² ΠΈ Π½Π° ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΠ΅ Π²ΠΎΠ·Π΄ΡΡ Π°
LG CH-04 ΠΠΊΠ»ΡΡΠ΅Π½Π° ΡΠΈΡΡΠ΅ΠΌΠ° Π·Π°ΡΠΈΡΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ
LG CH-05 ΠΡΠΈΠ±ΠΊΠ° ΠΎΠ±ΠΌΠ΅Π½Π° Π΄Π°Π½Π½ΡΠΌΠΈ ΠΌΠ΅ΠΆΠ΄Ρ ΠΊΠΎΠΌΠ½Π°ΡΠ½ΡΠΌ ΠΈ Π½Π°ΡΡΠΆΠ½ΡΠΌ Π±Π»ΠΎΠΊΠ°ΠΌΠΈ ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ
LG CH-06 Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΈΡ ΠΈΡΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΡΡ ΡΡΡΡΠΎΠΉΡΡΠ² Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° β ΡΠ΅Π»Π΅, ΠΊΡΠ°ΡΠΊΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ
LG CH-07 Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ Π²ΡΠ΅Π³ΠΎ Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° Π΄Π»ΠΈΡΠ΅Π»ΡΠ½ΠΎΠ΅ Π²ΡΠ΅ΠΌΡ Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ
LG CH-08 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π΄Π²ΠΈΠ³Π°ΡΠ΅Π»Ρ Π²Π΅Π½ΡΠΈΠ»ΡΡΠΎΡΠ°
LG CH-09 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ 4 β Ρ ΠΎΠ΄ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠ»Π°ΠΏΠ°Π½Π°
LG CH-10 ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π΅Π½ ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΊΠΎΡΠΏΡΡΠ° ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΡΠΏΠ»ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ (ΠΎΠ±ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅)
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΈΠ½Π²Π΅ΡΡΠΎΡΠ½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 21
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = IPM Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠ΅ΠΉ lg (ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ ΠΏΠΎ ΡΠΎΠΊΡ)
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 1 ΡΠ°Π·
Π‘Π»ΡΡΠ°ΠΉ- ΠΎΡΠΈΠ±ΠΊΠ° = ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ, IPM Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠ΅ΠΉ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 22
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ ΠΠ’ = 2 (ΠΌΠ°ΠΊΡ. ΡΠΎΠΊ)
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 2 ΡΠ°Π·Π°
Π‘Π»ΡΡΠ°ΠΉ ΠΎΡΠΈΠ±ΠΊΠΈ LG, β Π’ΠΎΠΊ 14Π
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 23
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ LG, β DC Π‘ΡΡΠ»ΠΊΠ° ΠΠΈΠ·ΠΊΠΈΠΉ Volt
LED01G (ΠΊΡΠ°ΡΠ½ΡΠΉ) = 2 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) = 3 ΡΠ°Π·Π°
Π‘Π»ΡΡΠ°ΠΉ ΠΎΡΠΈΠ±ΠΊΠΈ = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 140V
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 24
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = LG, β ΠΠΈΠ·ΠΊΠΎΠ΅ / ΠΡΡΠΎΠΊΠΎΠ΅ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =4 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β Low / High ΠΡΠ΅ΡΡ ΠΊΠΎΠΌΠΌΡΡΠ°ΡΠΎΡ ΠΎΡΠΊΡΡΡΠΎΠΌ ΡΠΈΠΊΠ»Π΅
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ lg = 26
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = DC ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ ΠΏΠΎΠ·ΠΈΡΠΈΠΈ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠΎΠ·ΠΈΡΠΈΡ ΠΎΠ±Π½Π°ΡΡΠΆΠ΅Π½ΠΈΡ ΠΎΡΠΈΠ±ΠΎΠΊ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 27
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = PSC Fault (ΡΠ΅Π°ΠΊΡΠΎΡ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =7 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ ΠΏΠΎ ΡΠΎΠΊΡ Π½Π° Β«IGBTΒ»
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 28
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = DC Π‘ΡΡΠ»ΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΠΠΎΠ»ΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =8 ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 420V
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 32
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π²ΡΠΏΡΡΠΊΠ½ΠΎΠΉ ΡΡΡΠ±Ρ Temp. ΠΡΡΠΎΠΊΠΈΠΉ (ΠΈΠ½Π². Compressor)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 3 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG Π²Π½ΡΡΡ. Π±Π»ΠΎΠΊΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β Π‘Π±ΡΠΎΡ Π΄Π°ΡΡΠΈΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ°. (105Β°C)
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 33
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π²ΡΠΏΡΡΠΊΠ½ΠΎΠΉ ΡΡΡΠ±Ρ Temp. ΠΡΡΠΎΠΊΠΈΠΉ (Cons. Compressor)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 3 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =3 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β Π‘Π±ΡΠΎΡ Π΄Π°ΡΡΠΈΠΊΠ° ΠΡΡΠΎΠΊΠ°Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ°. (105Β°C)
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 40
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = CT ΡΠ΅ΠΏΠΈ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) =
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΠ’ ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠ΅ΠΏΠΈ Off
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 41
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe Π΄Π°ΡΡΠΈΠΊΠ° INV. ΠΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 44
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄Π°ΡΡΠΈΠΊ Π²ΠΎΠ·Π΄ΡΡ
Π° (ΠΎΡΠΊΡΡΡΡ / ΠΠΎΡΠΎΡΠΊΠΈΠ΅
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =4 ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 45
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄ΠΈΡ. Π’ΡΡΠ±Π° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =5 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 46
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΡΠ°ΡΡΠ²Π°ΡΡΠ°Ρ ΡΡΡΠ±Π° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 47
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe ΠΠΈΠ½ΡΡΡ Sensor. ΠΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡ (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =7 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 48
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = D-Pipe & Π΄Π°ΡΡΠΈΠΊ Π²ΠΎΠ·Π΄ΡΡ
Π° (ΠΎΡΠΊΡΡΡΡΠΉ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 4 ΡΠ°Π·Π°
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =8 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΠ²ΠΎΠΉΠ½ΠΎΠΉ Π΄Π°ΡΡΠΈΠΊ ΠΎΡΠΊΠ»ΡΡΠ΅Π½. Π Π°Π·ΠΎΠΌΠΊΠ½ΡΡΠΎ ΡΠΎΠ΅Π΄ΠΈΠ½Π΅Π½ΠΈΠ΅ Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π½Π°Π³Π½Π΅ΡΠ°Π½ΠΈΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΈ Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²ΠΎΠ·Π΄ΡΡ
Π° Π² ΠΠ°ΡΡΠΆΠ½ΠΎΠΌ Π±Π»ΠΎΠΊΠ΅. ΠΠ΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎ ΠΏΡΠΎΠ²Π΅ΡΠΈΡΡ Π΄Π°ΡΡΠΈΠΊΠΈ ΠΈ ΠΈΡ
ΠΏΠΎΠ΄ΠΊΠ»ΡΡΠ΅Π½ΠΈΠ΅, ΡΠΎΠ΅Π΄ΠΈΠ½ΠΈΡΠ΅Π»ΡΠ½ΡΠ΅ ΠΏΡΠΎΠ²ΠΎΠ΄Π° Π»ΠΈΠ±ΠΎ ΠΏΠ»Π°ΡΡ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ.
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 51
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΠ° ΠΠΌΠΊΠΎΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 5 ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΠ° ΠΠΌΠΊΠΎΡΡΡ ΠΠΎΠΌΠ±ΠΈΠ½Π°ΡΠΈΡ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 53
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΠΡΠΈΠ±ΠΊΠ° ΡΠ²ΡΠ·ΠΈ (ΠΡΡΡΡΠΉ ΠΡΠΊΡΡΡΡΠΉ)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β 5 ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =3 ΡΠ°Π·Π°
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ»ΠΎΡ
ΠΎ / ΠΠΎΡΠ΅ΡΡ ΡΠ²ΡΠ·ΠΈ
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 60
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = EEPROM ΠΊΠΎΠ½ΡΡΠΎΠ»ΡΠ½ΠΎΠΉ ΡΡΠΌΠΌΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
LED02G (Π·Π΅Π»Π΅Π½ΡΠΉ) =
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΠΠΎΠ½ΡΡΠΎΠ»ΡΠ½Π°Ρ ΡΡΠΌΠΌΠ° Mis-Match
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 61
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = Π΄ΠΈΡ. Π’ΡΡΠ±Π° Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =1 ΡΠ°Π·
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠΎΠ½Π΄. Π’Π΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ° ΠΡΡΠΎΠΊΠΈΠΉ (65Β°C)
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 62
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ = ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡ ΡΠΏΠ»ΠΈΡ-ΡΠΈΡΡΠ΅ΠΌΡ LG Π²Π½ΡΡΡ. Π±Π»ΠΎΠΊΠ° ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΠΌΠΎΡΠ³Π½ΡΠ» 2-Π° ΡΠ°Π·Π°
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, β ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Temp. ΠΡΡΠΎΠΊΠΈΠΉ (85Β°C)
ΠΠΎΠ΄ ΠΎΡΠΈΠ±ΠΊΠΈ = 65
Π‘ΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΠ΅ = ΡΠ°Π΄ΠΈΠ°ΡΠΎΡΠ° Sensor (Open / Short)
Π‘Π²Π΅ΡΠΎ-Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ β ΠΌΠΈΠ³Π°Π΅Ρ 6-ΡΡ ΡΠ°Π·
Π‘Π²Π΅ΡΠΎΠ²ΠΎΠΉ Π΄ΠΈΠΎΠ΄ ΠΊΡΠ°ΡΠ½ΡΠΉ =5 ΡΠ°Π·
ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ β ΠΡΠΊΡΡΡΡ / ΠΊΠΎΡΠΎΡΠΊΠΎΠ³ΠΎ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΡ
ΠΠ΅ΠΏΠΎΠ»Π°Π΄ΠΊΠ° = ΠΠ°ΠΏΡΡΠΆΠ΅Π½ΠΈΠ΅ ΡΠ΅ΠΏΠΈ ΠΏΠΎΡΡΠΎΡΠ½Π½ΠΎΠ³ΠΎ ΡΠΎΠΊΠ° ΡΠ²Π»ΡΠ΅ΡΡΡ 420V
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΏΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΠ½ΡΡΡΠ΅Π½Π½ΠΈΠΉ Π±Π»ΠΎΠΊ:
ΠΠ½Π΅ΡΠ½ΠΈΠΉ Π±Π»ΠΎΠΊ:
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΡΠ»ΠΈ Π²Π°ΠΌ Π½Π΅ ΡΠ΄Π°Π»ΠΎΡΡ ΠΈΡΠΏΡΠ°Π²ΠΈΡΡ ΠΎΡΠΈΠ±ΠΊΠΈ ΠΈ ΡΡΡΡΠ°Π½ΠΈΡΡ ΠΏΠΎΠ»ΠΎΠΌΠΊΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΡΠ°ΠΌΠΎΡΡΠΎΡΡΠ΅Π»ΡΠ½ΠΎ β ΠΠ±ΡΠ°ΡΠΈΡΠ΅ΡΡ ΠΊ ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΡΡΠ°ΠΌ!
ΠΠ°Ρ ΠΎΠΏΡΡ Π±ΠΎΠ»Π΅Π΅ 5 Π»Π΅Ρ β ΠΠ²ΠΎΠ½ΠΈΡΠ΅, ΠΏΠΎΠΌΠΎΠΆΠ΅ΠΌ!
C1 ΠΈΠ»ΠΈ CH1 β Π²Π½ΡΡΡΠ΅Π½Π½ΠΈΠΉ Π΄Π°ΡΡΠΈΠΊ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΊΠΎΡΠΎΡΠΊΠΎΠ·Π°ΠΌΠΊΠ½ΡΡ ΠΈΠ»ΠΈ ΠΎΠ±ΡΡΠ² Π² ΡΠ΅ΠΏΠΈ;
ΠΠ°Π±ΠΎΡ ΠΊΠΎΠ΄ΠΎΠ² Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠ΅ΠΉ Π·Π°Π²ΠΈΡΠΈΡ ΠΎΡ ΠΌΠΎΠ΄Π΅Π»ΠΈ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ°. ΠΠΎΠ·ΠΌΠΎΠΆΠ½Π° ΠΈ ΡΠ°ΠΊΠ°Ρ ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΈΡ ΠΊΠΎΠ΄ΠΎΠ² Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠ΅ΠΉ Π² ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ°Ρ LG:
F01 β
ΠΠ±ΡΡΠ²/Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅ room ΠΊΠΎΠΌΠ½Π°ΡΠ½ΠΎΠ³ΠΎ (Π²ΠΎΠ·Π΄ΡΡΠ½ΠΎΠ³ΠΎ) Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²Π½ΡΡΡΠ΅Π½Π½Π΅Π³ΠΎ Π±Π»ΠΎΠΊΠ°
F02 β
ΠΠ±ΡΡΠ²/Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅ pipe Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²Π½ΡΡΡΠ΅Π½Π½Π΅Π³ΠΎ Π±Π»ΠΎΠΊΠ°
F03 β
ΠΡΡΡΡΡΡΠ²ΠΈΠ΅ ΡΠ²ΡΠ·ΠΈ ΠΌΠ΅ΠΆΠ΄Ρ ΠΏΡΠ»ΡΡΠΎΠΌ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ ΠΈ ΠΎΡΠ½ΠΎΠ²Π½ΠΎΠΉ ΠΏΠ»Π°ΡΠΎΠΉ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ Π±ΠΎΠ»Π΅Π΅ 2-Ρ ΠΌΠΈΠ½ΡΡ
F04 β
ΠΠ±ΡΡΠ²/Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅ pipe Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²Π½Π΅ΡΠ½Π΅Π³ΠΎ Π±Π»ΠΎΠΊΠ°
F05 β
ΠΠ±ΡΡΠ²/Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅ room Π²ΠΎΠ·Π΄ΡΡΠ½ΠΎΠ³ΠΎ Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π²Π½Π΅ΡΠ½Π΅Π³ΠΎ Π±Π»ΠΎΠΊΠ°
ΠΡΠ»ΠΈ ΡΠΈΡΡΠ΅ΠΌΠ° ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ° ΠΎΠ±Π½Π°ΡΡΠΆΠΈΠ»Π° Π±ΠΎΠ»Π΅Π΅ ΠΎΠ΄Π½ΠΎΠΉ ΠΎΡΠΈΠ±ΠΊΠΈ, Π²Π½Π°ΡΠ°Π»Π΅ ΠΈΠ½Π΄ΠΈΡΠΈΡΡΠ΅ΡΡΡ Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ, ΠΈΠΌΠ΅ΡΡΠ°Ρ Π½Π°ΠΈΠΌΠ΅Π½ΡΡΠΈΠΉ ΠΏΠΎΡΡΠ΄ΠΊΠΎΠ²ΡΠΉ Π½ΠΎΠΌΠ΅Ρ, Π° Π·Π°ΡΠ΅ΠΌ Π²ΡΠ΅ ΠΎΡΡΠ°Π»ΡΠ½ΡΠ΅ (ΠΏΠΎ Π²ΠΎΠ·ΡΠ°ΡΡΠ°Π½ΠΈΡ ΠΏΠΎΡΡΠ΄ΠΊΠΎΠ²ΠΎΠ³ΠΎ Π½ΠΎΠΌΠ΅ΡΠ° ΠΎΡΠΈΠ±ΠΊΠΈ). ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG ΠΏΡΠΈΠ²Π΅Π΄Π΅Π½Ρ Π² ΡΠ°Π±Π». 1.
Π’Π°Π±Π»ΠΈΡΠ° 1.
ΠΠΎΠ΄ Π½Π΅ΠΈΡ-ΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ | ΠΠΎΡΡΠ΄ΠΎΠΊ ΠΌΠΈΠ³Π°Π½ΠΈΡ ΡΠ²Π΅ΡΠΎΠ΄ΠΈΠΎΠ΄Π° Π² ΡΠ»ΡΡΠ°Π΅ Π²ΠΎΠ·Π½ΠΈΠΊΠ½ΠΎΠ²Π΅Π½ΠΈΡ Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ | ΠΠΎΠ·ΠΌΠΎΠΆΠ½Π°Ρ ΠΏΡΠΈΡΠΈΠ½Π° Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ | Π£ΡΡΡΠ°Π½Π΅Π½ΠΈΠ΅ Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ |
---|---|---|---|
1 | ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π²Π½ΡΡΡΠ΅Π½Π½Π΅Π³ΠΎ (ΠΊΠΎΠΌΠ½Π°ΡΠ½ΠΎΠ³ΠΎ) Π±Π»ΠΎΠΊΠ° Π°ΠΏΠΏΠ°ΡΠ°ΡΠ° β ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ° | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π±Π»ΠΎΠΊΠ° ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² ΠΊΠΎΠΌΠ½Π°ΡΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° | |
2 | ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ· ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² (ΡΠ°Π·ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ°: Π΄Π°ΡΡΠΈΠΊΠ° ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΏΠΎΡΡΡΠΏΠ°ΡΡΠ΅Π³ΠΎ Π²ΠΎΠ·Π΄ΡΡ Π° ΠΈΠ»ΠΈ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΡΡΡΠ±ΠΊΠΈ Π³Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠΎΠ½ΡΡΡΠ° | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π±Π»ΠΎΠΊΠ° ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠΎΠ² Π²Π½Π΅ΡΠ½Π΅Π³ΠΎ Π±Π»ΠΎΠΊΠ° | |
3 | ΠΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅Ρ ΡΠ°Π±ΠΎΡΠ°Π΅Ρ ΠΎΠ΄Π½ΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ ΠΈ Π½Π° ΠΎΠ±ΠΎΠ³ΡΠ΅Π² ΠΈ Π½Π° ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΠ΅ Π²ΠΎΠ·Π΄ΡΡ Π° | ΠΠΎΠ²ΡΠΎΡΠ½ΠΎ ΠΊΠΎΡΡΠ΅ΠΊΡΠ½ΠΎ ΡΡΡΠ°Π½Π°Π²Π»ΠΈΠ²Π°ΡΡ ΡΠ΅ΠΆΠΈΠΌΡ ΡΠ°Π±ΠΎΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠ°. ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠΈΡΡΠ΅ΠΌ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ Π½Π°Π³ΡΠ΅Π²ΠΎΠΌ ΠΈ ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΠ΅ΠΌ Π²ΠΎΠ·Π΄ΡΡ Π° | |
4 | ΠΡΠΊΠ»ΡΡΠ΅Π½Π° ΡΠΈΡΡΠ΅ΠΌΠ° Π·Π°ΡΠΈΡΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠΈΡΡΠ΅ΠΌΡ Π·Π°ΡΠΈΡΡ ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° ΠΎΡ ΠΏΠ΅ΡΠ΅Π³ΡΡΠ·ΠΊΠΈ | |
5 | ΠΡΠΈΠ±ΠΊΠ° ΠΎΠ±ΠΌΠ΅Π½Π° Π΄Π°Π½Π½ΡΠΌΠΈ ΠΌΠ΅ΠΆΠ΄Ρ ΠΊΠΎΠΌΠ½Π°ΡΠ½ΡΠΌ ΠΈ Π½Π°ΡΡΠΆΠ½ΡΠΌ Π±Π»ΠΎΠΊΠ°ΠΌΠΈ | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΊΠ°Π±Π΅Π»ΡΠ½ΡΠ΅ Π»ΠΈΠ½ΠΈΠΈ, Π° ΡΠ°ΠΊΠΆΠ΅ ΡΡ Π΅ΠΌΡ ΠΎΠ±ΠΌΠ΅Π½Π° Π΄Π°Π½Π½ΡΠΌΠΈ ΠΎΠ±ΠΎΠΈΡ Π±Π»ΠΎΠΊΠΎΠ² | |
6 | Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ ΠΎΠ΄Π½ΠΎΠ³ΠΎ ΠΈΠ»ΠΈ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΈΡ ΠΈΡΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΡΡ ΡΡΡΡΠΎΠΉΡΡΠ² Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° ΠΊΡΠ°ΡΠΊΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΈΡΠΏΠΎΠ»Π½ΠΈΡΠ΅Π»ΡΠ½ΡΡ ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° ΠΈ ΠΈΡ ΡΠ»Π΅ΠΌΠ΅Π½ΡΡ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ (ΠΊΠ»ΡΡΠ΅Π²ΡΠ΅ ΡΠΈΠ»ΠΎΠ²ΡΠ΅ ΡΡΠ°Π½Π·ΠΈΡΡΠΎΡΡ) | |
7 | Π’ΠΎΠΊ ΠΏΠΎΡΡΠ΅Π±Π»Π΅Π½ΠΈΡ Π²ΡΠ΅Π³ΠΎ Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° Π±ΡΠ» Π²ΡΡΠ΅ Π½ΠΎΡΠΌΡ | ΠΡΠΎΠ²Π΅ΡΡΡΡ Π΄Π°Π²Π»Π΅Π½ΠΈΠ΅ Ρ Π»Π°Π΄Π°Π³Π΅Π½ΡΠ΅ Π² ΡΠΈΡΡΠ΅ΠΌΠ΅, Π° Π·Π°ΡΠ΅ΠΌ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠ»Π΅ΠΌΠ΅Π½ΡΠΎΠ² Π½Π°ΡΡΠΆΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ° | |
8 | ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π΄Π²ΠΈΠ³Π°ΡΠ΅Π»Ρ Π²Π΅Π½ΡΠΈΠ»ΡΡΠΎΡΠ° | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ Π΄Π²ΠΈΠ³Π°ΡΠ΅Π»Ρ, Π° ΡΠ°ΠΊΠΆΠ΅ ΡΠ»Π΅ΠΌΠ΅Π½ΡΠΎΠ² ΡΡ Π΅ΠΌΡ Π΅Π³ΠΎ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ | |
9 | ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ 4 β Ρ ΠΎΠ΄ΠΎΠ²ΠΎΠ³ΠΎ ΠΊΠ»Π°ΠΏΠ°Π½Π° | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΠΊΠ»Π°ΠΏΠ°Π½Π° | |
10 | ΠΠ΅ΠΈΡΠΏΡΠ°Π²Π΅Π½ ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΊΠΎΡΠΏΡΡΠ° ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° (ΠΎΠ±ΡΡΠ² ΠΈΠ»ΠΈ ΠΊΠΎΡΠΎΡΠΊΠΎΠ΅ Π·Π°ΠΌΡΠΊΠ°Π½ΠΈΠ΅) | ΠΡΠΎΠ²Π΅ΡΡΡΡ ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΡ ΡΠ΅ΡΠΌΠΎΡΠ΅Π·ΠΈΡΡΠΎΡΠ° ΠΈ ΠΏΡΠΈ Π½Π΅ΠΎΠ±Ρ ΠΎΠ΄ΠΈΠΌΠΎΡΡΠΈ Π·Π°ΠΌΠ΅Π½ΡΡΡ Π΅Π³ΠΎ |
Π‘Π»Π΅Π΄ΡΠ΅Ρ ΠΎΡΠΌΠ΅ΡΠΈΡΡ, ΡΡΠΎ ΠΏΠΎΠ΄ΠΎΠ±Π½ΡΠ΅ ΠΎΡΠΈΠ±ΠΊΠΈ ΠΌΠΎΠ³ΡΡ Π²ΠΎΠ·Π½ΠΈΠΊΠ½ΡΡΡ Π² ΡΠ»ΡΡΠ°Π΅, Π΅ΡΠ»ΠΈ ΠΏΠ°ΡΠ°ΠΌΠ΅ΡΡΡ ΠΏΠΈΡΠ°ΡΡΠ΅ΠΉ ΡΠ΅ΡΠΈ (Π° ΡΠ°ΠΊΠΆΠ΅ Π΄ΡΡΠ³ΠΈΠ΅ ΠΏΠ°ΡΠ°ΠΌΠ΅ΡΡΡ β ΡΠΌ. ΠΈΠ½ΡΡΡΡΠΊΡΠΈΡ ΠΏΠΎ ΡΠΊΡΠΏΠ»ΡΠ°ΡΠ°ΡΠΈΠΈ Π½Π° ΠΊΠΎΠ½ΠΊΡΠ΅ΡΠ½ΡΠΉ ΡΠΈΠΏ Π°ΠΏΠΏΠ°ΡΠ°ΡΠ°) Π½Π΅ ΡΠ΄ΠΎΠ²Π»Π΅ΡΠ²ΠΎΡΡΡΡ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄ΡΠ΅ΠΌΡΠΌ Π·Π½Π°ΡΠ΅Π½ΠΈΡΠΌ, Π° ΡΠ°ΠΊΠΆΠ΅ Π² ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ ΡΠ»ΡΡΠ°ΠΉΠ½ΠΎΠ³ΠΎ ΡΠ±ΠΎΡ ΡΠΈΡΡΠ΅ΠΌΡ ΡΠΏΡΠ°Π²Π»Π΅Π½ΠΈΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠΌ. ΠΠΎΡΡΠΎΠΌΡ, ΠΏΡΠ΅ΠΆΠ΄Π΅ ΡΠ΅ΠΌ ΠΏΡΠΈΡΡΡΠΏΠΈΡΡ ΠΊ Π²ΡΡΠ²Π»Π΅Π½ΠΈΡ Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ ΠΈΠ»ΠΈ ΠΎΠ±ΡΠ°ΡΠ°ΡΡΡΡ Π² ΡΠΏΠΎΠ»Π½ΠΎΠΌΠΎΡΠ΅Π½Π½ΡΠΉ ΡΠ΅ΡΠ²ΠΈΡΠ½ΡΠΉ ΡΠ΅Π½ΡΡ LG, Π½Π΅ΠΎΠ±Ρ ΠΎΠ΄ΠΈΠΌΠΎ ΠΎΠ±Π΅ΡΡΠΎΡΠΈΡΡ Π°ΠΏΠΏΠ°ΡΠ°Ρ, ΠΏΡΠΎΠ²Π΅ΡΠΈΡΡ ΠΏΠΈΡΠ°ΡΡΡΡ ΡΠ΅ΡΡ, ΠΏΡΠ°Π²ΠΈΠ»ΡΠ½ΠΎΡΡΡ Π²ΡΠ±ΠΎΡΠ° ΡΠ΅ΠΆΠΈΠΌΠΎΠ² ΡΠ°Π±ΠΎΡΡ Π°ΠΏΠΏΠ°ΡΠ°ΡΠ°, Π° Π·Π°ΡΠ΅ΠΌ ΡΠ½ΠΎΠ²Π° Π²ΠΊΠ»ΡΡΠΈΡΡ Π΅Π³ΠΎ. Π Π½Π΅ΠΊΠΎΡΠΎΡΡΡ ΡΠ»ΡΡΠ°ΡΡ ΠΎΡΠΈΠ±ΠΊΠ° ΠΌΠΎΠΆΠ΅Ρ Π±ΠΎΠ»Π΅Π΅ Π½Π΅ Π²ΠΎΠ·Π½ΠΈΠΊΠ°ΡΡ.
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΏΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG.
ΠΠ½ΡΡΡΠ΅Π½Π½ΠΈΠΉ Π±Π»ΠΎΠΊ:
ΠΠ½Π΅ΡΠ½ΠΈΠΉ Π±Π»ΠΎΠΊ:
ΠΠΎΠ»Π½Π°Ρ Π²Π΅ΡΡΠΈΡ ΠΊΠΎΠ΄Π° ΠΎΡΠΈΠ±ΠΎΠΊ Ρ Π³ΡΠ°ΡΠΈΠΊΠ°ΠΌΠΈ Π·Π°Π²ΠΈΡΠΈΠΌΠΎΡΡΠΈ ΡΠΎΠΏΡΠΎΡΠΈΠ²Π»Π΅Π½ΠΈΡ Π΄Π°ΡΡΠΈΠΊΠΎΠ² ΠΎΡ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΈ ΠΌΠ΅ΡΠΎΠ΄Π°ΠΌΠΈ ΠΈΡ ΡΡΡΡΠ°Π½Π΅Π½ΠΈΡ:
ΠΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ Π²ΡΠ΅Ρ Π½Π°ΡΡΠ΅Π½Π½ΡΡ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG, Π² ΡΠΎΠΌ ΡΠΈΡΠ»Π΅ ΡΠ΅ΡΠΈΠΈ Art Cool
ΠΡΠ»ΠΈ ΠΊΠΎΠ΄Π° ΠΎΡΠΈΠ±ΠΊΠΈ Π½Π΅Ρ,Π° ΠΌΠΎΡΠ³Π°ΡΡ ΡΠ²Π΅ΡΠΎΠ΄ΠΈΠΎΠ΄Π½ΡΠ΅ ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡΡ Π½Π° ΠΏΠ°Π½Π΅Π»ΠΈ Π½Π΅ΠΎΠ±Ρ ΠΎΠ΄ΠΈΠΌΠΎ ΡΠΊΠ°ΡΠ°ΡΡ ΠΏΠΎΠ»Π½ΡΡ Π²Π΅ΡΡΠΈΡ ΠΊΠΎΠ΄Π° ΠΎΡΠΈΠ±ΠΎΠΊ, ΡΠ°ΠΌ ΠΆΠ΅ Π½Π°Ρ ΠΎΠ΄ΠΈΡΡΡ Π³ΡΠ°ΡΠΈΠΊ Π·Π°Π²ΠΈΡΠΈΠΌΠΎΡΡΠΈ ΡΠΎΠΏΡΠΎΡΠΈΠ²Π»Π΅Π½ΠΈΡ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ½ΠΎΠ³ΠΎ Π΄Π°ΡΡΠΈΠΊΠ° ΠΎΡ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ.
ΠΡΠ΅ ΠΊΠΎΠ΄Ρ ΠΎΡΠΈΠ±ΠΎΠΊ ΠΊΠΎΠ½Π΄ΠΈΡΠΈΠΎΠ½Π΅ΡΠΎΠ² LG
ΠΠΎΠ΄ Π½Π΅ΠΈΡΠΏΡΠ°Π²Π½ΠΎΡΡΠΈ
Π Π°ΡΡΠΈΡΡΠΎΠ²ΠΊΠ° ΠΊΠΎΠ΄Π° ΠΎΡΠΈΠ±ΠΊΠΈ
Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message.
Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor
Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor
Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor.
Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor.
Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power
Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power
RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float.
RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float.
Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21
Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21
Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06.
Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06.
RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound.
Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no
Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty.
RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound.
Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no
Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty.
RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8
Multi V indoor unit not connected to an outdoor unit. Check comms wiring is correct, and check initialisation has been carried out correctly
RAC Product = EEPROM Sum Check Error, text 60 for help.
RAC Product = PSC (Reactor) Error, text 27 for help.
RAC Product = Compressor Phase Current Error
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms, Check to earth 50 MOhm minimum, check run current
Inverter dc voltage low. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB
Splits and Multi Splits = High or low pressure trip. Low at 1 bar High at 35 bar check pressures. Multi V = High pressure trip.
Inverter compressor seized. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and Inverter outputs
Inverter current irregularity. Check inverter PCB, check reactor connections and its resistance is less than 1 ohm.
Inverter dc voltage too high. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter compressor discharge temperature too high. If over 105Β°C, check refrigerant charge
Excessive rise of standard compressor discharge temperature. If over 105Β°C check refrigerant charge
Excessive high pressure rise, over 35 bar at HP sensor. Check pressures, check coils, and filters are clean check for OFN in system pipework
Excessive low pressure drop under 1 Bar at LP sensor. Check pressures, and check service valves open
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter ac current abnormal. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and inverter outputs
Inverter compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168 kOhm at 30Β°C.
Low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar
High pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar
Outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C. If OK replace PCB, if not replace sensor
Outdoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20Β°C and 168 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Split/Multi Split = Outdoor unit discharge and air sensor both unplugged. Multi V = Outdoor unit coil sensor. Text 45 for diagnostics
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Comms error between outdoor main PCB and inverter PCB. Check wiring fuses and LEDs are lit. If OK either inverter or main PCB defective
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Outdoor unit PCB EEPROM failure, try removing EEPROM and refitting if removable (possible contact fault), otherwise replace PCB if the EEPROM is non-removable.
Condenser coil over 65Β°C. Check coil and filters are clean and free from debris, and airflow is OK. Check system pressures for non-condesables
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Outdoor unit inverter fin temperature sensor fault. Disconnect from PCB measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C
Outdoor Fan Motor siezed, or rotation sensing circuit failure. Check motor for mechanical and/or electrical failure, if okay replace pcb.
Excessive discharge temperature rise 105Β°C Sub condenser 1 standard compressor. Check refrigerant
Excessive discharge temperature rise 105Β°C Sub condenser 1 standard compressor. Check refrigerant
Excessive discharge temperature rise 105Β°C Sub condenser 2 standard compressor. Check refrigerant
Excessive discharge temperature rise 105Β°C Sub condenser 2 standard compressor. Check refrigerant
Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units
Communication error between outdoor main PCB and fan PCB. Check plug connections and LEDs. If OK, replace either main or fan PCB
Outdoor unit fan motor high current. Check fans rotate freely, and are connected correctly
Outdoor unit low voltage to fan PCB. Check 300 Vdc supply, check fuses and plug connections. If OK, replace fan PCB
Communication error between outdoor main PCB, and fan PCB. Check plug connections and LEDs. If OK replace either main or fan PCB
Sub 1 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 1 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault
Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units
Main outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Main outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Main outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 1 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar
Sub 1 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar
Sub 1 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C. If OK replace PCB, if not replace sensor
Sub 1 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. if not replace sensor
Sub 1 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168 kOhm at 30Β°C. if not replace sensor
Sub 1 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168 kOhm at 30Β°C. if not replace sensor
Sub 1 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 1 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 1 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 1 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 1 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 2 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar
Sub 2 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar
Sub 2 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C. If OK replace PCB, if not replace sensor
Sub 2 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C.if not replace sensor
Sub 2 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168kOhm at 30Β°C. if not replace sensor
Sub 2 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168kOhm at 30Β°C.if not replace sensor
Sub 2 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 2 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 2 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 2 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 2 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 2 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 2 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault
Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units
Sub 1 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 1 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 2 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 2 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 1 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%).check fuses, if fuses OK replace outdoor main PCB
Sub 1 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%). check fuses, if fuses OK replace outdoor main PCB
Sub 2 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%). check fuses, if fuses OK replace outdoor main PCB
Sub 2 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%). check fuses, if fuses OK replace outdoor main PCB
Faulty 4 way valve. Check solenoid coil and output from PCB. If OK, mechanical failure.
Excessive discharge temperature rise 105Β°C Sub condenser 2 standard compressor. Check refrigerant
Excessive discharge temperature rise 105Β°C Sub condenser 2 standard compressor. Check refrigerant
Sub 3 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 3 reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault
Communication error between Main and Sub outdoor units. Check comms wiring and power to all outdoor units
Sub 3 high pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar
Sub 3 low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar
Sub 3 outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C. If OK replace PCB, if not replace sensor
Sub 3 outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. if not replace sensor
Sub 3 compressor 1 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168 kOhm at 30Β°C. if not replace sensor
Sub 3 compressor 2 discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C and 168 kOhm at 30Β°C.if not replace sensor
Sub 3 outdoor unit coil sensor A fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 3 outdoor unit coil sensor B fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Sub 3 outdoor unit liquid pipe sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 3 outdoor unit Subcool inlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 3 outdoor unit Subcool outlet sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C
Sub 3 excessive rise of high pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 3 excessive drop of low pressure. Check pressures, check for non condensables, check heat exchanger coil is free from debris
Sub 3 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%). check fuses, if fuses OK replace outdoor main PCB
Sub 3 check power supply voltage to the outdoor unit is correct (1ph 220 Vac Β±10% or 3ph 380 Vac Β±10%). check fuses, if fuses OK replace outdoor main PCB
Main outdoor unit standard compressor not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty
Sub 1 standard compressor 1 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty
Sub 1 standard compressor 2 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty
Sub 2 standard compressor 1 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty
Sub 2 standard compressor 2 not starting. Check output from main PCB, check contactor, and check wiring connections. If OK compressor faulty
Comms Error between Outdoor Unit and HR Box No1. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB
Comms Error between Outdoor Unit and HR Box No2. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB
Comms Error between Outdoor Unit and HR Box No3. 1. Defective connection in HR unit power supply and transmission connection 2. Wrong setting of the HR unit Rotary switch and Dip switch 3. Defective HR unit PCB
Central controller wiring error. Check all comms wiring, including between controller and CNU, and IP addresses. If OK possible defective CNU
Central controller data sending error. Either defective CNU or Central controller initialisation failure
Central controller data receiving error. Either defective CNU or Central controller initialisation failure
Central controller. Comms cable too long or picking up external electrical noise. If OK, mismatching of controllers, or defective CNU
Central controller data receiving time out. Either defective CNU or Central controller initialisation failure
Central controller data sending time out. Either defective CNU or Central controller initialisation failure
Central controller data receiving time out. Either defective CNU or Central controller initialisation failure
Central controller data receiving error. Either comms cable picking up external electrical noise, or defective CNU
Central controller receiving no data. Either comms cable picking up external electrical noise, or defective CNU
Central controller incorrect address error. Check addresses match, if OK either comms cable picking up external electrical noise, or defective CNU
Central Controller Disconnection Error, No response from Air Conditioner. Check wiring, if OK either comms cable picking up external electrical noise, defective CNU, or Interface.
Indoor unit return air sensor fault, Open or Short. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor
Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor.
RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float.
Inverter compressor run current high. Check compressor windings all equal 1 to 4 Ohms, Check to earth 50 MOhm minimum, check run current
Splits = Compressor Over Current (CT2), also see Code 06.
RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound.
Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no
Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty.
Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB.
Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C, 168 kOhm at 30C.
RAC Product = EEPROM Sum Check Error, text 60 for help.
RAC Product = PSC (Reactor) Error, text 27 for help.
RAC Product = Compressor Phase Current Error
Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message.
Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor
Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor.
Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power
RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Commercial Product = Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float.
Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. Split = text 21
Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear. Splits = Compressor Over Current (CT2), also see Code 06.
RAC Indoor unit BLDC Fan problem. This is caused by the Indoor fan being locked. Check fan motor is plugged in correctly, Electrically & Mechanically sound.
Check the fan motor turns freely, check the AC Voltage supplied to the fan motor, this will vary from 120 V ac at low speed to 170V AC at high speed. If no
Voltage is present the the PCB is faulty, if Voltage is present the fan motor will be Faulty.
Split = Outdoor unit fan problem. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB. Multi V = indoor PCB failure. Replace PCB
RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20Β°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8
Multi V indoor unit not connected to an outdoor unit. Check comms wiring is correct, and check initialisation has been carried out correctly
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter compressor run current high. Check compressor windings all equal 1 to 4 OhmsCheck to earth 50 MOhm minimum, check run current
Inverter dc voltage low. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB
Splits and Multi Splits = High or low pressure trip. Low at 1 bar High at 35 bar check pressures. Multi V = High pressure trip.
Inverter compressor seized. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and Inverter outputs
Inverter current irregularity. Check inverter PCB and reactor
Inverter dc voltage too high. Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. If OK change outdoor inverter PCB
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter compressor discharge temperature too high. If over 105Β°C, check refrigerant charge
Excessive rise of standard compressor discharge temperature. If over 105Β°C check refrigerant charge
Excessive high pressure rise, over 35 bar at HP sensor. Check pressures, check coils, and filters are clean check for OFN in system pipework
Excessive low pressure drop under 1 Bar at LP sensor. Check pressures, and check service valves open
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Inverter ac current abnormal. Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and inverter outputs
Inverter compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20C and 168 kOhm at 30C.
Low pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar
High pressure sensor fault. Check dc voltage between white and black cable on plug. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar
Outdoor unit air sensor fault. Disconnect from PCB and measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C. If OK replace PCB, if not replace sensor
Outdoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10Β°C and 4 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20Β°C and 168 kOhm at 30Β°C. If OK replace PCB, if not replace sensor
Split/Multi Split = Outdoor unit discharge and air sensor both unplugged. Multi V = Outdoor unit coil sensor. Text 45 for diagnostics
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Reverse or open phase. Check all 3 phases are present and correct. If correct voltage appears at all three phases, swap any two to cure the fault
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Comms error between outdoor main PCB and inverter PCB. Check wiring fuses and LEDs are lit. If OK either inverter or main PCB defective
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Outdoor unit PCB EEPROM failure, try removing EEPROM and refitting if removable (possible contact fault), otherwise replace PCB if the EEPROM is non-removable.
Condenser coil over 65Β°C. Check coil and filters are clean and free from debris, and airflow is OK. Check system pressures for non-condesables
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
no such fault code Text 1, 2 or 3 digit fault code number only. If you see fault code CH07 only type 7 in your text message
Outdoor unit inverter fin temperature sensor fault. Disconnect from PCB measure resistance. 8 kOhm at 30Β°C and 13 kOhm at 20Β°C
Outdoor Fan Motor siezed, or rotation sensing circuit failure. Check motor for mechanical and electrical failure.
CL = Child Lock. Press Timer & Min buttons simultaneously for 5 seconds to engage/disengage function.
Text the 1, 2 or 3 digit fault code number only. I.e. If you see fault code CH07 on your indoor unit or R/Controller, only type 7 or 07 in your text message.
Condensate pump float switch risen. Check drain pan is empty, check pump is working OK. If no pump check blue jumper plug is inserted in socket CN Float. Alternatively, Dry Contact Interface is in «OFF» condition. Check status and adjust as necessary.
Po = Jet Cool Mode selected. To cancel press Jet Cool, Fan Speed or Set Temperature button.